Keri-systems Doors.NET Manual Manual do Utilizador Página 509

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 508
Doors.NET Reference Manual
- 509 -
Global Linkage - Program an Output to
Follow an Input
To program a Global Linkage you must have a Global Linkage license enabled and you
must be using Mercury Powered NXT or Standard Mercury controllers.
This example uses a monitor point (input) to activate a control point (output relay). The
input can be a monitored door a motion detector and the output can be a red led or a
buzzer. The LED or the buzzer would provide an indication that the door has been
opened, or if there has been movement detected in a secure area.
This example uses an input and an output on NXT 4x4 modules. Both controllers have a
4x4 on bus #1.