6. The dedicated Global Unlock input is a normally-open circuit that activates Global
Unlock when it’s closed. It is physically located between pins 5 and 6 of TB4 on
the PXL controller. This input can alternately be designated as an Auxiliary RTE
input, but this function is automatically disabled when global unlock is enabled.
7. Now if this input on the master controller is activated, all online PXL doors will
unlock and appropriate messages are posted in Live Events.