IRP-1 Isolation Relay
Installation Guide
Page 1 of 4 P/N: 01833-001 Rev. H
1.0 Purpose
Keri controllers are designed with built-in voltage transient suppression. The controller ship kits also provide external
transorbs that Keri recommends installing. For most applications, this level of protection is more than adequate. However,
there are certain applications that can require additional protection. Typically these are:
1. Magnetic locks and similar devices
2. Dry-contact devices for use with heavy-duty solenoids such as turnstiles, vehicle gates, and overhead doors
For these applications, the IRP-1 should be used to isolate the controller from the transients these devices can generate,
ensuring reliable protection and operation of the controller.
2.0 Kit Contents
The IRP-1 kit is made up of the following items:
One relay PCB
One transorb (1.5KE39C nonpolarized)
Double sticky-sided foam tape (for PCB mounting)
3.0 Specifications
The isolation relay is rated at 12 A max @ 28 VDC.
4.0 Wiring Diagrams
This document provides generic drawings for wiring to an external locking device (such as a magnetic lock or door strike)
and to a dry-contact device (such as a switch or relay controlling a motor for a parking barrier or power gate). Please refer
back to the Installation Guide for the Keri controller you are installing to determine the specific Terminal Blocks and Pins
to which these wiring connections are made.
There are two wiring paths shown from the external lock to the N/O and N/C connections: one for a Fail-Secure device
and one for a Fail-Safe device. Review the drawing and ensure you are making the correct connection for your
application.
NOTE Install the supplied transorb as near to the external locking device or dry-contact device as possible. Do not install
the transorb if the device is being powered with greater than 12 VDC.
Vista de página 0
1 2 3 4

Resumo do Conteúdo

Página 1 - 4.0 Wiring Diagrams

IRP-1 Isolation RelayInstallation GuidePage 1 of 4 P/N: 01833-001 Rev. H1.0 PurposeKeri controllers are designed with built-in voltage transient suppr

Página 2

IRP-1 Isolation RelayInstallation GuidePage 2 of 4 P/N: 01833-001 Rev. H4.1 Wiring to an External Locking DeviceN/O N/CCOM–+IRP-1–+12 VDCController P

Página 3

IRP-1 Isolation RelayInstallation GuidePage 3 of 4 P/N: 01833-001 Rev. H4.2 Wiring to a Dry Contact DeviceN/O N/CCOM–+IRP-1–+12 VDCController Power Su

Página 4 - 5.0 Contact Keri Systems

IRP-1 Isolation RelayInstallation GuidePage 4 of 4 P/N: 01833-001 Rev. H5.0 Contact Keri Systemsend of documentKeri USA Keri UK, Ireland, Europe2305