Keri-systems BioPointe Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Software Keri-systems BioPointe. Keri Systems BioPointe User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - BioPointe Central

BioPointe Centralfor Windows

Página 2

Biopointe Central User’s ManualGetting Started612) Click on the button and the installation is complete and a shortcut is installed on thedesktop.

Página 3 - TABLE OF CONTENTS

Biopointe Central User’s ManualGetting Started716) Enter information as requested and submit it when ready.

Página 4

Biopointe Central User’s ManualGetting Started8C. Uninstalling BioPointe CentralFor both Windows 95/98 and Windows 2000/XP un-installation processes,

Página 5 - Chapter 1

Biopointe Central User’s ManualSystem Overview9Chapter 3 System Overview AuthorizedApplicationUsersDevice UsersEvent LogsDevice Users’Access Rights12

Página 6 - Chapter 2

Biopointe Central User’s ManualSystem Overview10Encompassed within BioPointe Central are a few databases. The first stores a list of application users

Página 7

Biopointe Central User’s ManualBasic Operation11Chapter 4 Basic operationThis chapter gives you quick and concise instructions to perform basic funct

Página 8

Biopointe Central User’s ManualBasic Operation12A. Log on as Default UserWhen you start BioPointe Central, you will be prompted to enter the UserID an

Página 9

Biopointe Central User’s ManualBasic Operation13B. Change Default PasswordFor security reasons, you may decide to change the default password (“PASSWO

Página 10

Biopointe Central User’s ManualBasic Operation14C. Create New Application’s UserYou can create a new application user or supervisor through User SetUp

Página 11 - Getting Started

Biopointe Central User’s ManualBasic Operation15To add a new Device into the Device Table:1. Click Tools from the top menu and select Device Manageme

Página 12

Biopointe Central User’s ManualNoticesInformation in this document is subject to change without notice. NO WARRANTY OF ANY KIND IS MADE WITH REGARD TO

Página 13 - Chapter 3

Biopointe Central User’s ManualBasic Operation166. To change the communication settings, click the Device Connection Setup button. The DeviceConnecti

Página 14

Biopointe Central User’s ManualBasic Operation17E. Create Device User RecordsThis process is also known as enrollment, where you can enroll new device

Página 15 - Chapter 4

Biopointe Central User’s ManualBasic Operation183. The UserID field is filled in with a default ID that increments every time a new record is created

Página 16 - A. Log on as Default User

Biopointe Central User’s ManualBasic Operation199. You will see the Fingerprint Enrollment / Verification Center. The instructions from the instructi

Página 17 - B. Change Default Password

Biopointe Central User’s ManualBasic Operation20F. Assign User Access Right to a BioPointe DeviceOnce the user has been given access rights to a speci

Página 18 - D. Create Device Table

Biopointe Central User’s ManualBasic Operation213. Click to move the multiple-select User Ids into the Selected User ListNOTE:To select multiple us

Página 19

Biopointe Central User’s ManualBasic Operation222. Select Download page.3. Check the All check box to select all the users in the user’s list for do

Página 20

Biopointe Central User’s ManualAdvance Features23Chapter 5 Advance FeaturesThis chapter describes the advance features provided by the BioPointe Cent

Página 21 - E. Create Device User Records

Biopointe Central User’s ManualAdvance Features24(2) Click the Edit button to open the fields for edit mode.(3) Click the Add button. The following

Página 22

Biopointe Central User’s ManualAdvance Features25(5) Select the features by double clicking on the Access Id and click OK to commit the change.NOTE:O

Página 23

Biopointe Central User’s Manual TABLE OF CONTENTSINTRODUCTION...

Página 24

Biopointe Central User’s ManualAdvance Features26NOTE:If the Biopointe device has enabled the secure communication mode (ie master fingerprinttemplate

Página 25

Biopointe Central User’s ManualAdvance Features27To read and set device time and date(1) Select Device ID.(2) Click Get button to read the date and

Página 26

Biopointe Central User’s ManualAdvance Features28(4) Click Save button to save changes into the database.(5) Click to download the new configurati

Página 27 - Chapter 5

Biopointe Central User’s ManualAdvance Features29To Copy from device to multiple devices:1) Select the source device and then click on the “Copy” But

Página 28 - Advance Features

Biopointe Central User’s ManualAdvance Features30To upload device properties from the device:To use upload device configuration feature:1) Select Dev

Página 29

Biopointe Central User’s ManualAdvance Features31Device propertiesProperties Options DescriptionUser ID 3 – 10 # of user digits used as the User ID. W

Página 30 - Device Management System

Biopointe Central User’s ManualAdvance Features32Device advance propertiesProperties Options DescriptionNormalVerify levelHighThe security verificatio

Página 31 - Device parameters setting

Biopointe Central User’s ManualAdvance Features33Upload event log recordsTo upload device log records:(1) Click Tools from the top menu and select De

Página 32

Biopointe Central User’s ManualAdvance Features34To start the log export function:Under the Device Management System, click Log Export.

Página 33

Biopointe Central User’s ManualAdvance Features35Following section provide a full description on all the functions provide by the export log interface

Página 34

Biopointe Central User’s ManualH. CARD READER COM PORT SETTINGS...

Página 35 - Device properties

Biopointe Central User’s ManualAdvance Features36A) Device Log TypeDevice Log allows you to select which kind of Log information is to be exported na

Página 36 - Device advance properties

Biopointe Central User’s ManualAdvance Features37E) Fill DefaultFill Default option allows you to control the size of the exported fields. When the c

Página 37 - Upload event log records

Biopointe Central User’s ManualAdvance Features38Event Log Records report Under the Device Management System, click Log Report.There are 4 types of lo

Página 38

Biopointe Central User’s ManualAdvance Features39IconsGenerate selected type of report based on the filter setting.Purge selected type of record in th

Página 39

Biopointe Central User’s ManualAdvance Features40To purge log records(1) Select which type of log report you want to purge.(2) Check the filter chec

Página 40

Biopointe Central User’s ManualAdvance Features41C. User Management SystemThe user management system provides the following advance features:(1) Batc

Página 41

Biopointe Central User’s ManualAdvance Features42(3) Select the devices and click Batch Download. Note to select multiple devices, press “Ctrl” keyto

Página 42

Biopointe Central User’s ManualAdvance Features43(3) Select the device id from the Device List and click .(4) Select the user id from the FP User

Página 43 - To generate report

Biopointe Central User’s ManualAdvance Features44(4) Upon completion on the upload process, select the desired user id from the upload user list and

Página 44 - Log Export

Biopointe Central User’s ManualAdvance Features45(4) Enter the desire user id into the UserID edit box and click Search.(5) If the user id is found

Página 45 - User Management System

Biopointe Central User’s ManualIntroduction1Chapter 1 INTRODUCTIONA. How BioPointe Central WorksBioPointe Central is used for maintaining and adminis

Página 46

Biopointe Central User’s ManualAdvance Features46(3) Select the device id from the Device List and click .(4) Select the user id from the FP User

Página 47

Biopointe Central User’s ManualAdvance Features47(4) Click Copy and the following dialogue box will be shown:(5) Select the device from the Device T

Página 48

Biopointe Central User’s ManualAdvance Features48Device users’ access right cross checkThis feature allows administrators to verify whether the device

Página 49

Biopointe Central User’s ManualAdvance Features49D. Setting Finger Print ScannerSetting the Finger Scanner Type is used to define which model fingerpr

Página 50

Biopointe Central User’s ManualAdvance Features50E. Calibrate Finger Print ScannerThis feature allows administrators to perform a calibration on the f

Página 51

Biopointe Central User’s ManualAdvance Features51NOTE:Once the modem is manually connected, the modem will stay connected until you have manuallydisco

Página 52 - Error log report

Biopointe Central User’s ManualAdvance Features52(2) Select the device from the Device Table and click on the Selected Device ID button. Or click on

Página 53 - Setting Finger Print Scanner

Biopointe Central User’s ManualAdvance Features53(2) Select which type of Card Reader.(3) Select the com port that the card reader is connected to a

Página 54 - Modem Connection System

Biopointe Central User’s ManualAdvance Features54K. Card Data ImportCard Data Import function provides a way for the user to import pre-defined Card n

Página 55 - Device Log Management System

Biopointe Central User’s ManualAdvance Features55(2) Click Tools from the top menu and select Database Path Setup from the drop-down menu.(3) Select

Página 56 - Card Reader Com Port Settings

Biopointe Central User’s ManualGetting Started2Chapter 2 GETTING STARTEDA. System RequirementsYou will need the following: Pentium PC or compatible

Página 57 - Expiry Date Configuration

Biopointe Central User’s ManualAdvance Features56Comma separator separates the field with a comma (,). Eg field1, field2, field3, field4, field5Fixed

Página 58 - Database Path Setup

Biopointe Central User’s ManualAdvance Features57D) ImportImport option allows you to import all the text file’s data into the user database. System

Página 59 - Import User Information

Biopointe Central User’s ManualAdvance Features58O. User Records FilteringWhen user log on to the application, all the user records will be shown and

Página 60 - C) Import Linkage

Biopointe Central User’s ManualAdvance Features59P. Database MaintenanceThe application provides the features like re-index, pack, empty, backup, rest

Página 61 - Export User Information

Biopointe Central User’s ManualAdvance Features60(3) Click OK to start the packing operation.To empty the database:(1) Click Database from the top m

Página 62 - User Records Filtering

Biopointe Central User’s ManualAdvance Features61NOTE:Do a backup occasionally on the database files to help user recover any data loss. Close anyopen

Página 63 - Database Maintenance

Biopointe Central User’s ManualAdvance Features62Database Setup allows user to change the properties of the displayed database table. User cannot chan

Página 64

Biopointe Central User’s ManualAdvance Features63Field Definition module allows user to change the display name and the properties of thedisplay field

Página 65 - Database Setup

Biopointe Central User’s ManualAdvance Features64S. Configure FingerPrint Scanner TypeThe Biopointe Central package supports two types of fingerprint

Página 66 - Edit Database Settings

Biopointe Central User’s ManualAdvance Features65T. Support Multiple Export Formats for Report The Biopointe Central Package support the following exp

Página 67

Biopointe Central User’s ManualGetting Started33) Click on the BioPointe Software and Documentation link. The BioPointe installation window appears.4

Página 68

Biopointe Central User’s ManualAdvance Features66(b) Select the required format from the drop list and provide the file name.(c) Press the Save butt

Página 69

Biopointe Central User’s ManualTroubleShooting67Chapter 5 TROUBLESHOOTINGIf you have any difficulty using Biopointe Central, the troubleshooting sugg

Página 70

Biopointe Central User’s ManualAppendix A68Appendix Appendix AList of Log Record States Table 4.6(a) to 4.6(f) lists the different class of log reco

Página 71

Biopointe Central User’s ManualAppendix A69Time-Attendance logs will record one of the following events in the table above. This event isselected by t

Página 72 - Appendix

Biopointe Central User’s ManualAppendix A70Table 4.6(c): Alarm Events (Trace Event)Identifier(hex)Identifier(dec)Description1 0x30 48 Alarm Activated2

Página 73

Biopointe Central User’s ManualAppendix A71Table 4.6(e): Setup Mode Events (Trace Event)Identifier(hex)Identifier(dec)Description1 0xA0 160 Setup Mode

Página 74

Biopointe Central User’s ManualAppendix B72 Appendix BList of Database filesThere are two types of database files namely, Biopointe Data Files and Sy

Página 75

Biopointe Central User’s ManualAppendix B73Biopointe Data Files FPSchUsr.MDXBiopointe Data Files FPUplTem.DBFBiopointe Data Files FPUplTem.DBTBiopoint

Página 76 - Appendix B

Biopointe Central User’s ManualAppendix C74 Appendix CList of Function Status and Reader Error CodeThis section describes the Function Status and Rea

Página 77 - Export User Information Table

Biopointe Central User’s ManualAppendix C7516FAIL_TO_CONVERT_TEMPLATE 0xCF Fail to convert template to proper format17ABORT_FINGER_CAPTURE 0xD0 Fing

Página 78 - Appendix C

Biopointe Central User’s ManualGetting Started45) Wait as the InstallShield Wizard prepares to install BioPointe to your system.6) Once the Welcome

Página 79

Biopointe Central User’s ManualAppendix C7647INVALID_SCHEDULE_CNT_IN_INI_FILE 0x9aThere was a invalid entry in the Sch.ini file48GENERAL_FILE_SYSTEM_E

Página 80

Biopointe Central User’s ManualAppendix C778INVALID_PARAMETER0xA6 An invalid parameter was passed in to thefunction9RECEIVE_FOOTER_WRONG0xA7 Expected

Página 81

Biopointe Central User’s ManualAppendix C78 The Reader returns this list of error codes (Table 6(b)) if the command fails.Table 6(c): List of Error C

Página 82

Biopointe Central User’s ManualAppendix C7928TIME_OUT0x1B Reader has timed-out while waiting fora packet from Host29DATA_BEING_PURGED0x1C Data from Ho

Página 83

Biopointe Central User’s ManualAppendix C8057INVALID_PIN_NUMBER0x38 PIN number must not be zero duringenrolment58NO_PIN_WRITTEN0x39 No PIN was registe

Página 84

Biopointe Central User’s ManualAppendix C81 11M2ERROR_DB_NO_DATA0x5B Database has no data 12M2ERROR_EXTRACT_FAIL0x5CFailed capturing feature points of

Página 85

Biopointe Central User’s ManualAppendix C82 38M2ERROR_CHECKSUM_ERROR0xFE Checksum error 39M2ERROR_UNKNOWN_COMMAND0xFF Command was not recognized

Página 86

Biopointe Central User’s ManualGetting Started59) Verify the correct folder is selected for installation. Keri recommends using the default destinati

Comentários a estes Manuais